TimeEdit: Difference between revisions

From UmsWiki
Jump to navigation Jump to search
Kia (talk | contribs)
Kia (talk | contribs)
No edit summary
Line 55: Line 55:


Users will still be uploaded to TimeEdit.[[File:TimeEdit Settings Exclude Students.jpg|none|thumb|447x447px]]
Users will still be uploaded to TimeEdit.[[File:TimeEdit Settings Exclude Students.jpg|none|thumb|447x447px]]
==Metadata configuration==
{| class="wikitable"
|'''Important information'''
TimeEdit has a limit in the database, a maximum of 20 data fields on a timeblock  can be returned. If you map too many metadata the integration will fail.
|}
This lets you define which fields in UMS are sent to corresponding fields in TimeEdit.
Create 4 metadata configurations for
*employees
*activities
*courses
*students
Students are predefined by UMS, no setup is needed.
Some fields are predefined for the metadata settings while other are required if you are extracting [[GetTimetable/TimeEdit|Timetable blocks]].
All fields are from the '''Students''' table.[[File:TimeEdit Settings Metadata.jpg|none|thumb|902x902px]]
===Key name===
The name of the field in TimeEdit.
===Static text before database field===
The text you write in this field will be suffixed to the UMS database field value.
===UMS database field===
The database field in the UMS table Students.
===Static text after database field===
The text you write in this field will be postfixed to the UMS database field value.
===Required===
UMS will not send the record to TimeEdit If this field is empty when it generates the data to send. This will also be logged in to TimeEdit.Log file.


=== [[TimeEditFields|TimeEdit field information]] ===
=== [[TimeEditFields|TimeEdit field information]] ===

Revision as of 08:20, 19 February 2020

Prerequisites

Module requirements

  • UMS
  • TimeEdit account

Create TimeEdit settings on templates

Edit a template and apply settings for TimeEdit in order to send data from UMS to TimeEdit

Upload of courses fails if no courses are imported on GetStudents. Verify this with SQL

select distinct Skolefag from ImportFromDB


Description

Enter a name for this setting.

Upload courses

Upload courses from UMS to TimeEdit. This is courses as defined by UMS

Activities/groups upload can not be disabled.

TimeEdit Server connection

All connection information is provided by TimeEdit support.

All information is specific to a customer.

URL (Endpoint)

This URL specifies the endpoint that UMS connects to.

Certificate path

Then XML file you receive from TimeEdit. The certificate must be issued to your school, else you will get this error

Username

Username to access the Webservice URL.

Password

Password to access the Webservice URL.

Employee mail domain

This will be appended to the username to complete a mail address that TimeEdit can use.Example: @inlogic.dk

Students mail domain

This will be appended to the username to complete a mail address that TimeEdit can use. Example: @inlogic.dk

If students are using private mails then leave the field blank and configure metadata where you map general.email with UMS field PrivateMail


Exclude students from classes

Username entered here will prevent them from being member of any activities.

Users will still be uploaded to TimeEdit.

TimeEdit field information

Configure Modules > Timetable >Datasource

Create a new datasource in order to get timetable blocks in return from TimeEdit

FAQ

Missing subject / title

Titles in timetable are based on ActivityDescription in UMS (TimeEdit key: studentclass.longdecript).

If bookings are not bound to activities then fill out the comments field in TimeEdit. The Comment field is also displayed on the body text of the booking.


There is no field with ext.id "person.first_name" , "general.email" etc

The missing fields must be configured in the TimeEdit database. You can do this either by making a supportrequest to TimeEdit or download a an administrative tool from TimeEdit, please contact TimeEdit for further information.

How can I test a TimeEdit certificate ?

Download the SoapUI tool and send a soap register-request as shown in the screenshot. If the certificate is registreret correctly at TimeEdit the response will be the key used for 2 factor authentication.